RDU-18 Radiation Sensor Specifications


Home

Passive Detection™

Products

Q & A

Contact Us


Background Information

Detector

Halogen-quenched Neon Geiger-Mueller gamma detector
Stainless Steel Window

Sensitivity

18 cps/mR/Hr gamma radiation (from isotopes such as 137Cs, 60Co, 238Pu, and other fission products, and fissile materials 232Th, 235U and 239Pu.)
10 cpm detector background

Alert Threshold

Thresholds are provided for 4 levels:

Alert Level
Threshold
Minimum Detectible Level
Alarm threshold referenced to mean background Geiger event period and 1 ppm probability threshold.  Most sensitive to transient exposures for application in portals and traffic choke points.
Aprox. 50 µR/hr
LOW
Aprox. 1 mR/hr
MODERATE
Aprox. 10 mR/hr
HIGH
Aprox. 100 mR/hr, or Saturated Detector

Interface

4-Wire, AWG 20-26 Gauge
Internal Screw Terminal Connections:
Terminal
Connection
1
V+ Input, 9-15 Volts, D.C., 25 mA
2
Serial Data +
3
Serial Data -
4
Ground

NOTE: The RDU-18 can be configured to provide a contact closure for interface to Security/Alarm systems, or for other applications involving robotic or automated systems.  Please contact TRD Associates for further information on this option.

Housing

ABS plastic
4.53 x 2.56 x 1.58 inches
IEC 529 - IP65, NEMA-4X rated, dust/waterproof
Sealed Cable Gland/Strain Relief

Operating Temperature

-20 to +70 C





Protected by US Patent #7,327,270.  Other patents pending.